PIEZOELECTRIC ACCELEROMETER
PEA300
Piezoelectric IEPE uniaxial accelerometer
PEA300 measures dynamic acceleration using a ceramic planar-shear sensing element and an integrated IEPE amplifier. Its titanium housing, side-mounted coaxial connector and electrically isolated mounting base suit modal analysis and general-purpose vibration testing.
- Frequency response / ±10%
- 1–10000 Hz
- Mass
- 10 g
- Output
- IEPE
- Measurement range
- ±10–±500 g
01 / OVERVIEW
Every connection serves the measurement.
PEA300 measures dynamic acceleration using a ceramic planar-shear sensing element and an integrated IEPE amplifier. Its titanium housing, side-mounted coaxial connector and electrically isolated mounting base suit modal analysis and general-purpose vibration testing.
Ceramic planar-shear element
For dynamic acceleration measurements.
Broad frequency response
1–10000 Hz (±10%) for common vibration testing frequencies.
IEPE output
Six measurement ranges from ±10 to ±500 g.
Electrically isolated base
Isolation resistance ≥10 GΩ.
Titanium housing
Side-mounted 10-32 coaxial connector.
Applications
- Modal analysis
- Vibration control
- General-purpose vibration monitoring
02 / SPECIFICATIONS
Compare. Then configure.
Select a range above to compare sensitivity, broadband resolution and other specifications.
| Parameter | Unit | ||||||
|---|---|---|---|---|---|---|---|
| Ordering code | — | SCA00101 | SCA00102 | SCA00103 | SCA00104 | SCA00105 | SCA00106 |
| Performance | |||||||
| Sensitivity | mV/g | 500 | 200 | 100 | 50 | 20 | 10 |
| Sensitivity tolerance | % | ±5 | |||||
| Frequency response (±10%) | Hz | 1~10000 | |||||
| Resonant frequency | kHz | >36 | |||||
| Broadband resolution | g rms | 0.00013 | 0.0003 | 0.0004 | 0.0010 | 0.0020 | 0.0030 |
| Linearity* | % FS | ±1 | |||||
| Transverse sensitivity | % | ≤5 | |||||
| Strain sensitivity (250 µε) | g/µε | 0.002 | |||||
| Electrical | |||||||
| IEPE constant-current excitation | mA | 2~20 | |||||
| Compliance voltage | VDC | 18~30 | |||||
| Output impedance (typical) | Ω | 100 | |||||
| Bias voltage | VDC | 11~13 | |||||
| Discharge time constant | s | 0.5~1.5 | |||||
| Electrical isolation resistance | GΩ | ≥10 | |||||
| Environmental | |||||||
| Maximum vibration | g pk | 200 | 300 | 400 | 500 | 600 | |
| Maximum shock | g pk | 5000 | |||||
| Operating temperature | °C | -55~+121 | |||||
| Sealing | — | Hermetic | |||||
| Mechanical | |||||||
| Sensing element / construction | — | Ceramic / planar shear | |||||
| Mass | g | 10 | |||||
| Housing / connector material | — | Titanium | |||||
| Electrical connector | — | 10-32 coaxial, side-mounted | |||||
| Mounting interface | — | 10-32 UNF-2B, thread depth 3 mm | |||||
| Mounting torque | N·m | 1.2~2.2 | |||||
| Parameter | ±50 g |
|---|---|
| Ordering code | SCA00103 |
| Performance | |
| Sensitivity | 100mV/g |
| Sensitivity tolerance | ±5% |
| Frequency response (±10%) | 1~10000Hz |
| Resonant frequency | >36kHz |
| Broadband resolution | 0.0004g rms |
| Linearity* | ±1% FS |
| Transverse sensitivity | ≤5% |
| Strain sensitivity (250 µε) | 0.002g/µε |
| Electrical | |
| IEPE constant-current excitation | 2~20mA |
| Compliance voltage | 18~30VDC |
| Output impedance (typical) | 100Ω |
| Bias voltage | 11~13VDC |
| Discharge time constant | 0.5~1.5s |
| Electrical isolation resistance | ≥10GΩ |
| Environmental | |
| Maximum vibration | 400g pk |
| Maximum shock | 5000g pk |
| Operating temperature | -55~+121°C |
| Sealing | Hermetic |
| Mechanical | |
| Sensing element / construction | Ceramic / planar shear |
| Mass | 10g |
| Housing / connector material | Titanium |
| Electrical connector | 10-32 coaxial, side-mounted |
| Mounting interface | 10-32 UNF-2B, thread depth 3 mm |
| Mounting torque | 1.2~2.2N·m |
Ranges correspond to ±5 V output. Sensitivity test for ±10 g: 1 g, 160 Hz, 24°C; other ranges: 1 g rms, 100 Hz. * Linearity uses a zero-based straight line, expressed as full scale. IEPE excitation must be current-limited to 20 mA maximum.
Spectral noise / ±10 g range
| Hz | 1 | 10 | 100 | 1000 | 10000 |
|---|---|---|---|---|---|
| Noise / µg rms/√Hz | 340 | 130 | 36 | 21 | 12 |
03 / DIMENSIONS & MOUNTING
Check the fit. Plan the installation.
Dimensions in mm. Overall length: 19.45 mm; height: 16.20 mm; hex width: 12.70 mm; base diameter: 12.40 mm.
- Side-mounted 10-32 coaxial connector; 10-32 UNF-2B mounting thread, thread depth 3 mm.
- Recommended mounting torque: 1.2–2.2 N·m. Mounting contact area: TIR ≤0.03 mm; Ra ≤1.6 µm.
- See PEA300-INST Rev A (initial release) for the mounting stud, mounting hole and complete installation requirements.